We wrote it once so nobody has to explain it to each person separately again: every app screen and every menu of the Windows software, with real screenshots and a line-by-line explanation.
This section is the training that until now was given in person. It is three pages, in order: read this page first to get used to the words and colours, then go to the app or the Windows software. Each section has a real picture of that screen, and under the picture we have written what each part is.
You don't have to read all of it. If you only want to see the plant on your phone, "The first 5 minutes" at the bottom of this page followed by the app guide is enough — about 15 minutes. The Windows software guide is for whoever sits at the plant computer.
All three are connected to the same data. The difference is where you are sitting.
If you have never seen any of them, take just these few steps. The rest of the guide explains these very steps.
If you know these, you can read any NuraNet screen — even one this guide doesn't cover.
| Word | What it means |
|---|---|
| Inverter | The box that turns the panels' direct current (DC) into the grid's alternating current (AC). A plant has one to dozens of inverters, and in NuraNet each has a number: #1, #2 … |
| String | Several panels connected in series to one inverter input. It is the smallest unit a failure can be attributed to. |
| MPPT | The inverter's smart input, which sets each string's voltage so the most power is drawn from it. A large inverter may have 10 MPPT inputs, and each MPPT one or more strings. |
| kW versus kWh | kW is power, "how much right now"; kWh is energy, "how much over time". 78 kW means this moment; 3861 kWh means from the morning until now. |
| Efficiency / PR | The ratio of actual energy to the energy expected with this irradiance and this capacity. A percentage that sums up the state of the whole plant in one number. |
| Error / alarm | A code reported by the inverter itself. It means the device knows it has a problem. |
| AI finding | No error is recorded, but the behaviour has drifted from the normal pattern — for example a string producing half of what its neighbours do. We keep these apart from errors because they are a different kind of thing. |
| Inverter outage versus loss of connection | "Inverter outage" means the plant is reachable but one inverter isn't responding. "Plant connection lost" means the plant itself no longer sends data and all the figures are stale. |
| Modbus / RS485 | The language and the wire with which the Windows software reads data directly from the inverters. If Modbus Status is down, no new figure comes in. |
These seven colours are the same in the Windows software, the app, the web version, the company monitoring center and the station portal. Learn a colour once and it means the same thing everywhere.
The order has meaning too. When a plant has several states at once, the worst of them decides the card's colour: loss of connection outranks error, error outranks inverter outage, and inverter outage outranks an AI finding. So a red card means "definitely has an error", not "only has an error".
Start from the task you have in mind, not from the menu.
| I want to… | App | Windows software | Web portal |
|---|---|---|---|
| see how much the plant is producing right now | The plant card in the list | Total Power at the top of the window | The plant screen |
| find out which inverter has stopped | The "Inverters 7/7" counter and the inverter details section | Online and the All Inverters window | The inverter table |
| see the last 30 days' production | Energy meter | View › Energy Meter | Energy report |
| get a financial and revenue report | — | Energy financial report (from the energy meter) | Energy report |
| find the cause of today's production drop | Data analysis + alerts | Solar AI and Power Analyse | — |
| find a faulty string | Inverter details → per-string table | MPPT Layout and panel arrangement | — |
| define and follow up a maintenance job | — | Maintenance | — |
| get alerts on my phone | Background monitoring in the settings | — | — |
No. The Windows software is installed on the plant's own computer and talks directly to the inverters; the app reads from the server. If you are the owner or a manager and don't sit at the plant, the app alone is enough.
The Android version has an install file. On the iPhone, open the web version in Safari and tap "Add to Home Screen"; it has the same screens. Background notifications and fingerprint login work only on Android.
No. Each account is tied to one device; the new phone waits for the administrator's approval, and until it is approved the previous phone keeps working.
Every screen writes the time of the last update. If the data is not fresh, NuraNet does not show a stale figure without a label: the card turns orange and says plainly that the data is old.
Not in the app — the app only reads. In the Windows software, configuration changes (panel layout, connection settings) need separate access and are closed to ordinary users. For risk-free practice, the app's "Guest login" works with sample data.
If part of the guide was unclear, or the screen you see differs from what is here, tell us — we will tell you what to do, and fix this page too.
The same number answers on WhatsApp, Telegram, Eitaa and Bale.