Industries · Oil, gas, refining and petrochemicals

Instrumentation and energy management for oil, gas, refining and petrochemicals

Vacuum and pressure gauges made in Iran for process and laboratory, and energy-management and power-quality software for the complex — with technical documents, testing and direct support from the manufacturer.

In a refinery or petrochemical plant, vacuum and pressure are not just a number on a panel: the quality of the distillation column's cuts, the ejectors' steam consumption, catalyst life and the safety of the unit depend on them. A large share of the gauges that give these numbers are imported, and supplying, repairing and finding spares for them is hard. Paya Electronic Salimi (Kasian) stands beside this industry on two levels, with vacuum and pressure gauges made in Iran and energy-management software.

Measuring vacuum and pressure in the process

Applications and the recommended gauge

ApplicationRecommended gaugeEngineering note
Top of the vacuum distillation column (VDU)Capacitance PT100The gas composition (hydrocarbon vapour and water) varies; a gas-independent gauge is neededPirani for monitoring pump-down
Steam ejector systems and vacuum pumpsPirani + capacitancePirani for monitoring each stage and interlocks, capacitance for controlling the final pressure
Dryers and catalyst / molecular-sieve regenerationPiraniMonitoring the pump-down trend and the end of drying from the vacuum curve
Transformer oil treatment and vacuum fillingPirani DGConfirming the specified vacuum is reached before oil is filled, at substations and power plants
Vacuum insulation of cryogenic equipment and double-walled linesPiraniA drop in insulation vacuum is the sign of a leak, before it leads to icing and losses
Refinery laboratory — vacuum distillationCapacitanceDistillation testing at reduced pressure needs an accurate, gas-independent pressure reading
Instrument-gas and nitrogen pressure, and leak testingPositive-pressure capacitancePressure-decay testing of vessels and lines; range to order

Safety: the standard version of the gauges has no explosion-proof (Ex) certification. In classified areas, installation is in a safe area with a sample line, or inside an approved Ex enclosure with a safety barrier — according to the project's safety design and the client's approval.

Why made in Iran

What matters to the operations unit and procurement

Reliable supply

No dependence on imports or sanctions; predictable delivery times and spare parts within reach.

Repairability

The board, firmware and sensor are designed in-house; the sensor is repaired or replaced instead of discarding the whole gauge.

Replacing an existing gauge

Range, output and process connection are designed to match your current gauge, so it can be replaced without changes to the control system.

Self-diagnosis

An open or short-circuited sensor and electronic faults are reported as error codes, and the analogue output goes to a defined fault level.

Technical documents

Datasheet, test and calibration report for supplier qualification and delivery.

Engineering collaboration

Designing a special version for one application — range, gas, temperature, output — tested alongside your team.

Energy Management

Power quality, demand and the site's solar plant

Oil, gas and petrochemical complexes are among the largest electricity consumers, and large motors with variable-speed drives create harmonics and a poor power factor.

Inquiry

For a quick inquiry, send us these

  1. Pressure range and type of measurementVacuum or positive pressure, gauge or absolute, and the window that must be read accurately.
  2. Process gas or vapourApproximate composition, presence of water vapour, condensate or corrosive gas.
  3. Process connection and temperatureFlange or thread type, and the temperature at the installation point.
  4. Output and control systemAnalogue, 4–20 mA, serial or Modbus; whether a display is needed.
  5. Area classification of the installation pointSafe or hazardous area, so that a safe installation solution can be proposed.
FAQ

Common questions — oil, gas and petrochemicals

Which gauge suits a refinery vacuum unit?

The pressure at the top of a vacuum distillation column is usually in the tens of millibar, and its gas is a mixture of hydrocarbon vapour and steam; since the composition is not constant, a capacitance gauge, which does not depend on gas type, is the better choice. Pirani is enough for monitoring pump-down and interlocks.

Are the gauges certified for hazardous areas?

The standard version has no explosion-proof certification, and we say so plainly. In classified areas the gauge is installed in a safe area with a sample line, or inside an approved Ex enclosure with a safety barrier — according to the project's safety design and the client's approval.

Does the gauge output connect to a DCS?

Yes; analogue output and a serial port are standard, and a 4 to 20 mA or Modbus output is designed for projects that need it.

Do you provide technical documents for supplier qualification?

Datasheets, test and calibration reports and the product's technical documentation are provided for the qualification process and registration on the approved-vendor list.

Do you also monitor the site's solar plant or a remote station?

Yes; with the NuraNet Link data logger, NuraNet monitors a solar plant with no computer, even over a SIM card, and sends alerts to your phone.

Read on

More instrumentation

We work with your operations or procurement unit

Send us the datasheet or the specifications of your current gauge; we will send a technical proposal, documents and price.

The same number answers on WhatsApp, Telegram, Eitaa and Bale.