Vacuum and pressure gauges made in Iran for process and laboratory, and energy-management and power-quality software for the complex — with technical documents, testing and direct support from the manufacturer.
In a refinery or petrochemical plant, vacuum and pressure are not just a number on a panel: the quality of the distillation column's cuts, the ejectors' steam consumption, catalyst life and the safety of the unit depend on them. A large share of the gauges that give these numbers are imported, and supplying, repairing and finding spares for them is hard. Paya Electronic Salimi (Kasian) stands beside this industry on two levels, with vacuum and pressure gauges made in Iran and energy-management software.
| Application | Recommended gauge | Engineering note |
|---|---|---|
| Top of the vacuum distillation column (VDU) | Capacitance PT100 | The gas composition (hydrocarbon vapour and water) varies; a gas-independent gauge is neededPirani for monitoring pump-down |
| Steam ejector systems and vacuum pumps | Pirani + capacitance | Pirani for monitoring each stage and interlocks, capacitance for controlling the final pressure |
| Dryers and catalyst / molecular-sieve regeneration | Pirani | Monitoring the pump-down trend and the end of drying from the vacuum curve |
| Transformer oil treatment and vacuum filling | Pirani DG | Confirming the specified vacuum is reached before oil is filled, at substations and power plants |
| Vacuum insulation of cryogenic equipment and double-walled lines | Pirani | A drop in insulation vacuum is the sign of a leak, before it leads to icing and losses |
| Refinery laboratory — vacuum distillation | Capacitance | Distillation testing at reduced pressure needs an accurate, gas-independent pressure reading |
| Instrument-gas and nitrogen pressure, and leak testing | Positive-pressure capacitance | Pressure-decay testing of vessels and lines; range to order |
Safety: the standard version of the gauges has no explosion-proof (Ex) certification. In classified areas, installation is in a safe area with a sample line, or inside an approved Ex enclosure with a safety barrier — according to the project's safety design and the client's approval.
No dependence on imports or sanctions; predictable delivery times and spare parts within reach.
The board, firmware and sensor are designed in-house; the sensor is repaired or replaced instead of discarding the whole gauge.
Range, output and process connection are designed to match your current gauge, so it can be replaced without changes to the control system.
An open or short-circuited sensor and electronic faults are reported as error codes, and the analogue output goes to a defined fault level.
Datasheet, test and calibration report for supplier qualification and delivery.
Designing a special version for one application — range, gas, temperature, output — tested alongside your team.
Oil, gas and petrochemical complexes are among the largest electricity consumers, and large motors with variable-speed drives create harmonics and a poor power factor.
Harmonic monitoring to IEEE 519 and EN 50160, demand and peak load, reactive-power penalties and the bill with Iran's tariffs, on your existing analyzers.
TavanaNet page › NuraNet — flagship productFor the solar plants that complexes build to cover part of their own electricity or to meet renewable-energy requirements: real-time monitoring, AI fault detection and standard reports; and for remote sites, NuraNet Link with no computer.
NuraNet page ›The pressure at the top of a vacuum distillation column is usually in the tens of millibar, and its gas is a mixture of hydrocarbon vapour and steam; since the composition is not constant, a capacitance gauge, which does not depend on gas type, is the better choice. Pirani is enough for monitoring pump-down and interlocks.
The standard version has no explosion-proof certification, and we say so plainly. In classified areas the gauge is installed in a safe area with a sample line, or inside an approved Ex enclosure with a safety barrier — according to the project's safety design and the client's approval.
Yes; analogue output and a serial port are standard, and a 4 to 20 mA or Modbus output is designed for projects that need it.
Datasheets, test and calibration reports and the product's technical documentation are provided for the qualification process and registration on the approved-vendor list.
Yes; with the NuraNet Link data logger, NuraNet monitors a solar plant with no computer, even over a SIM card, and sends alerts to your phone.
Send us the datasheet or the specifications of your current gauge; we will send a technical proposal, documents and price.
The same number answers on WhatsApp, Telegram, Eitaa and Bale.