Monitoring multiple analyzers
Femto (Iranian) and Schneider PM2220/PM2230 analyzers on one RS-485 bus with Modbus RTU; each device with its own address, CT/PT ratio and role.
TavanaNet is a product of Paya Electronic Salimi (Kasian): a system that reads the factory's power analyzers on an industrial bus, analyses power quality based on international standards, calculates the electricity bill with Iran's tariffs and uses AI to recognise the behaviour of industrial loads — built on the same professional platform as NuraNet.
From reading the analyzers on an industrial bus to power-quality analysis, the electricity bill, maintenance and reporting.
Femto (Iranian) and Schneider PM2220/PM2230 analyzers on one RS-485 bus with Modbus RTU; each device with its own address, CT/PT ratio and role.
A live card for each analyzer (voltage, current, power, power factor, THD, demand), the site total, and power and frequency trend charts.
Automatic calculation of energy in the four tariff periods, demand charges and the reactive-power penalty — per meter or for the whole site.
THD, individual harmonics, phasors, voltage unbalance and events, assessed against IEEE 519, EN 50160 and the IEC 61000-4-30 classes.
Behavioural models of 11 types of industrial load; analyzer data is interpreted according to the load type and produces maintenance findings.
Alarms for voltage, frequency, THD, power factor, unbalance and loss of communication, with event logging based on ISA 18.2, sound and a window indicator.
Live condition-based findings from analyzer data, one-click work orders, and a preventive-maintenance catalogue for transformers, capacitors, motors and panels.
Batched writing, a threshold-based harmonic archive and a daily energy ledger for each meter — designed for years of operation without slowing down.
User accounts with access levels (RBAC), a bilingual Persian/English interface and dark and light themes.
TavanaNet splits the energy consumed into Iran's four tariff periods — mid-load, peak, off-peak and Friday peak — calculates the 15-minute demand windows with the server's exact clock (not the meter's unreliable clock) and shows the statutory reactive-power penalty for a power factor below 0.9. The result: a bill forecast, the expensive hours identified, and production planning to cut costs.
High harmonics mean overheated transformers and cables, drive faults and unexplained trips. TavanaNet assesses power quality continuously.
Voltage and current THD and individual harmonics up to the 31st order, with a threshold-based archive to track the history.
IEEE 519 limits (TDD), the EN 50160 profile and event classification per IEC 61000-4-30.
Voltage and current phasor diagram, phase unbalance and neutral current — early signs of equipment faults.
Every industrial load has its own electrical signature: the 5th and 7th harmonics of a 6-pulse drive, the flicker of an arc furnace, the inrush of a DOL motor start. With 11 behavioural models of industrial load, TavanaNet interprets each analyzer's data according to the type of load it is reading, and delivers actionable findings instead of raw numbers.
The "condition AI" layer learns each feeder's normal behaviour directly from the analyzer archive — with no manual labelling and no external dependencies.
The baseline is built by "hour of the week", because consumption at 10 a.m. on Saturday is not the same as at 10 p.m. on Friday. It is measured robustly (median and MAD) so that a single spike cannot poison the baseline.
When an indicator moves slowly towards its limit, a robust slope (Theil–Sen) is calculated on the daily medians and an estimate of the number of days until the limit is crossed is given — a chance to plan, not a warning at the moment of crisis.
Each analyzer gets a health score built from weighted penalties: harmonics, unbalance, neutral load, power factor, anomalies, drift and data coverage. The contribution of each component is shown — an unexplained score is worthless to an industrial audience.
The analysis runs on hourly aggregates; a month of two-second sampling becomes a few hundred rows. The result: it runs on any site computer in a background thread, and its output is fully deterministic and explainable — not a black box.
At the factory, it reads the analyzers on the RS-485 bus, analyses and archives.
The same proven, encrypted infrastructure as NuraNet; signed data and device authentication.
The factory's energy and power-quality status, alerts and bill forecast — any moment, anywhere.
TavanaNet collects the data of the factory's power analyzers in real time, analyses power quality and harmonics based on IEEE 519 and EN 50160, calculates the electricity bill with Iran's four-period tariff and uses AI to recognise the behaviour of industrial loads.
Yes. Energy in the four tariff periods, demand charges and the cosφ<0.9 reactive penalty are calculated per meter or for the whole site, and the month's bill forecast is shown.
Femto (Iranian) and Schneider PM2220/PM2230 are supported out of the box, all on one RS-485 bus with Modbus RTU. New models can be added through the modular architecture — contact us to check compatibility.
NuraNet is designed for solar plants (inverters and strings) and TavanaNet for factories and industry (power analyzers, the electricity bill and industrial loads). Both are built on one shared platform and have the same server and mobile infrastructure.
Request one from the contact section on this page, or by calling or messaging +98 913 163 1095 on WhatsApp or Telegram; Paya Electronic Salimi (Kasian)'s specialists will arrange it with you.
Contact Paya Electronic Salimi (Kasian) for a free TavanaNet demo, technical advice and pricing.