Four pieces of hardware, the Windows software beside the plant, the owner's app, and the company monitoring centre. Each is written on its own, so it is clear what it reads, what it calculates and what it shows.
The names are close and the jobs are not. The 485 converter is only the wire. Two loggers are for a plant with no computer, and they differ in how they reach the internet. Link R sits beside a computer that is already reading the plant.
| Link (485) | Link (WiFi) | Link (LTE) | Link R (LTE) | |
|---|---|---|---|---|
| Job | RS-485 to USB converter | Data logger, in place of a computer | The same logger | Line backup, beside the computer |
| Reading and analysis on the device itself | — | Yes | Yes | Only while it holds the line |
| Internet | — | Wi-Fi only | Wi-Fi, otherwise a 4G SIM | Wi-Fi and a 4G SIM |
| Sits beside | Plant computer | In place of a computer | In place of a computer | Beside the computer, on the same line |
A plain RS-485 to USB converter. It does not read an inverter, calculate a number or connect to the server. It brings the panel's RS-485 line to the plant computer's USB port so the NuraNet Windows software can read that line.
A data logger for a plant with no computer, whose internet comes from the site's Wi-Fi. It has no SIM. If Wi-Fi drops, the data stays on the device and is sent when Wi-Fi returns. There is no second path to the internet.
The same as Link (WiFi), except that it has both Wi-Fi and a 4G SIM. If Wi-Fi really reaches the internet it sends over Wi-Fi. Otherwise the SIM connects. When Wi-Fi returns, the SIM hangs up so the data bundle is not spent.
The line backup, for a plant that has a computer and the Windows software. It is not the primary reader. It sits on the same inverter RS-485, listens, and stays quiet while the computer is talking.
The backup behaviour on its own: NuraNet Link R. The logger for a plant with no computer: NuraNet Link.
On the computer beside the plant. It collects the data itself. The internet only carries the result to the server. While the internet is down, reading and analysis continue and the result is sent once the link is back. The HMI, the plant-design review and Plant Viewer exist only in this software.
| Windows software | |
|---|---|
| Reads | Inverter registers over RS-485, and Modbus TCP where it is present: voltage, current and power of each MPPT and string, three-phase voltage, current and frequency, active and reactive power, power factor, module and heatsink temperature, daily and total energy, fault and warning codes, and online state. Up to 8 power meters and analyzers: voltage, current, power, power factor, THD, energy, frequency and interval current peak. Individual harmonics. Where fitted, an irradiation sensor and ambient temperature. A weather forecast for the site. |
| Measures | The plant's instantaneous power, today's energy and calendar ranges, whether each inverter is online, voltage and current quality on the analyzer, and string balance from the real current and voltage. If there is no irradiation sensor, efficiency is left blank. A zero or a clear-sky guess is not put in its place. |
| Calculates | PR and specific yield on IEC 61724 when irradiation has been measured. Expected energy, and the split between a shortfall of sun and a shortfall of the plant itself. Each string and each inverter against its neighbours at the same moment. Loss in kilowatt-hours per day and an estimate in rials. A suggested MPPT and string count from the current, and a panel count from the voltage. Whether the settings match what the inverter itself reports. Power quality on IEEE 519, EN 50160 and IEC 61000-4-30. Local sunrise and sunset, so a "zero production" warning is not raised at night. |
| Shows | An overview of power and energy, a history chart, a layout coloured by state, a designable HMI, the single line, each inverter with its MPPT and string table, an energy meter with the Persian calendar and revenue, the alarm centre, the maintenance log and reports. Persian, English and Arabic, without reversing the menu layout. |
| Features | Several USB converters for several RS-485 runs. Several owners on one computer, each seeing only their own inverters. Alarms with acknowledgement and shelving. Work orders and preventive maintenance. CSV, Excel and PDF export. A local archive and a copy of the plant folder on a second disk or an external disk. Signed upload to the server. Part of the plant set remotely, and put back if the result is not sound. Signed updates. Link state with the place of the break: the local network, DNS, the internet or the server. |
The longer list of what it does: All the capabilities.
Android, and a web version on an iPhone and in any browser. The app does not connect to the plant. It reads from the server. Android has instant alerts, background watching and fingerprint sign-in. Each account is tied to one device. A new device waits for the administrator, and the previous device keeps working until then. When the data is not fresh it does not show a stale number, and the plant card turns orange.
The Link installer's app is a different thing: only beside the device, over Bluetooth, to commission Link and Link R.
| The owner's app | |
|---|---|
| Reads | The plant's latest message from the server: power, energy, efficiency, weather, each inverter's state, inverter alarms, AI findings, and each owner's share when the plant is shared. |
| Measures | It does not measure on the line. It shows the same numbers the computer or the Link read at the plant. |
| Calculates | It builds the energy range and the chart from the server's history. It separates capacity and the sale price for that user's share. Fault finding is done at the plant, and the app brings the result. |
| Shows | A list of plants coloured by state. A dashboard of power, today's energy, efficiency and weather. An energy meter per inverter. Inverter detail, temperature and faults. Inverter alarms and AI findings in two separate groups. Persian, Gregorian and lunar calendars. Light and dark theme. Persian and English. |
| Features | An instant alert for an inverter fault or an inverter that dropped off. PDF and Excel reports from the phone itself. The administrator's messages inside the app. The owner's reply on a finding: it was real, it was nothing, it is fixed. A user who owns only some of the inverters sees only that share. |
nuraanet.ir/company is for a team that watches several plants together. Each user sees every plant briefly on the map and opens only the plants they have been given. The station portal, nuraanet.ir/station, is separate: one plant's dashboard in the browser, for that site's operator, with nothing to install.
| Company monitoring center | |
|---|---|
| Reads | The plants' messages from the server: power, energy, inverter state, alarms, AI findings, the power analyzer, weather, layout and single line, and the software and firmware version. |
| Measures | The measurement was made at the site. The centre shows the fresh number. If no message arrives it marks the state as lost, not the last number with no label. |
| Calculates | Plants sorted by severity. The marker colour from state, weather, or power against capacity. If the computer does not send the loss list, the server builds the same comparison from the data it has stored. |
| Shows | A map of every plant, and a list with the worst state at the top. Each plant's page: overview, inverters, DC, energy, analysis, comparison, events, layout, single line, power quality, AI, maintenance, weather, reports, system. |
| Features | Search, a state filter, a weather layer, colour by power or PR, a control-room mode, distance and routing. PDF and Excel reports, in Persian or English. Software and firmware version on the system tab. Each user's access to each plant is set separately. |
Say whether the site has a computer, and whether the internet comes from Wi-Fi or has to be a SIM.
The same number answers on WhatsApp, Telegram, Eitaa and Bale.