A small data logger in the plant's electrical panel that reads the inverters, analyses the data itself, sends it to the server over Wi-Fi or a SIM and keeps the data through an internet outage. It runs a plant with no computer on its own. Set-up takes only a phone. The backup for a plant that has a computer is the separate product NuraNet Link R.
Many solar plants are built where land is cheap and sun is plentiful — and for exactly that reason nobody is there. There is no control room, no operator and no reliable internet. A computer in the panel may not come back up after a power cut, its Windows wants updates, and there is nobody to connect a monitor and keyboard to it.
NuraNet Link is NuraNet's hardware data logger: a small, low-power device in the plant's electrical panel, with no moving parts, that reads the inverters over the RS-485 line and every 15 minutes sends the same information a plant computer would to the NuraNet server, over Wi-Fi or its built-in 4G SIM.
To the server, the owner's app, the company site and the admin panel, NuraNet Link is exactly like a plant computer: the same charts, the same alarms, the same reports.
| Plant computer + NuraNet software | NuraNet Link | |
|---|---|---|
| Inverter data and alarms on the server, app and site | Yes | Yes, the same message |
| Working without internet and sending later | Yes | Up to about 31 days |
| Built-in SIM internet | — | Yes |
| Remote configuration and updates | Yes | Yes |
| Artificial Intelligence | Complete | Lighter: DC inputs, inverters, grid voltage |
| Power analyzer | Yes | Yes |
| HMI screen, plant design, Plant Viewer | Yes | — |
| Cost, power consumption and space | Higher | Very low |
A simple rule: where nobody is on site or the plant is small, NuraNet Link; where there is an operator and a control room that wants a big screen, a plant computer. The backup for that computer is another product: NuraNet Link R.
An orange light tells the status without opening the app: fast blinking = the set-up window is open, two blinks = no internet, slow blinking = the server is not connected, one short flash every 3 seconds = everything is fine.
In NuraNet, collection and analysis happen at the plant — on the plant computer or NuraNet Link — and the cloud is only the way the result reaches you.
| Situation | A fully cloud-based system | NuraNet |
|---|---|---|
| Data collection during an outage | Stopped | Continues |
| Analysis and fault diagnosis during an outage | Stopped | Continues |
| Data from the outage days | Lost forever | Sent after reconnecting |
| Display during an outage | A blank screen | An explicit "connection lost" state, not a stale number |
| Bandwidth needed | Constant and heavy | Compressed packets at configurable intervals |
The plant computer is configured and updated the same way. Security details ›
Tell us where it is and which inverters it has — we will define the solution and its cost for you.
The same number answers on WhatsApp, Telegram, Eitaa and Bale.